Mass Flow Meters: Instructions for Use
Mass flow meters​ are precision instruments that measure the mass of a fluid moving through a pipe.

Mass flow meters​ are precision instruments that measure the mass of a fluid moving through a pipe. Unlike volumetric flow meters, they do not rely on the volume of the fluid. Instead, they measure the actual mass, which remains constant under varying temperature and pressure conditions. This makes mass flow meters highly reliable for critical processes.

Mass flow meters are used in many industries. These include oil and gas, chemical production, pharmaceuticals, and food processing. They are often chosen when accuracy and repeatability are essential. For example, in blending operations or chemical dosing, a small error in flow can result in product waste or safety hazards.

There are different types of mass flow meters. The two most common types are Coriolis and thermal mass flow meters. Both have different working principles, but the setup, use, and maintenance share common steps. These steps help ensure accurate performance and a long service life.

In this article, we will explain how to use mass flow meters properly. We will cover preparation, installation, calibration, daily operation, and maintenance. These instructions apply to most general-purpose mass flow meters, but users should always refer to the manufacturer’s manual for specific models.

Preparing for Installation

Before installing a mass flow meter, it is important to understand the process conditions. This includes knowing the type of fluid, its temperature, pressure, and flow rate range. These values must fall within the operating range of the flow meter.

The pipe size and material should also be considered. The meter must fit the pipe without causing leaks or turbulence. Make sure the pipe is clean and free from debris before installation.

Check that all necessary tools and fittings are available. The installation site should be easy to access. It should also be protected from mechanical vibrations, extreme temperatures, or moisture, which can affect readings.

In some cases, it is helpful to install shutoff valves around the meter. This makes future maintenance easier and allows for isolation without stopping the entire process.

Installing the Mass Flow Meter

Mass flow meters must be installed correctly to provide accurate measurements. For Coriolis flow meters, the sensor tubes must be mounted according to the direction of flow. Most meters have arrows on the body to show the correct direction.

The orientation of the meter is also important. For liquid measurements, it is better to install the meter in a vertical position with upward flow. This helps remove any trapped air bubbles. For gas measurements, horizontal orientation is often preferred.

Avoid installing the meter near pumps, valves, or elbows. These can cause flow disturbances. If this cannot be avoided, allow a certain length of straight pipe upstream and downstream. This allows the fluid to stabilize before entering the meter.

Thermal mass flow meters require special care if the gas is not clean. In such cases, filters should be installed upstream. This protects the sensors from dust or oil that can affect the heat transfer.

All electrical connections must be secure. Follow the wiring diagram provided by the manufacturer. Use shielded cables if the environment has electrical noise. Make sure the power supply matches the meter’s voltage rating.

Calibrating the Meter

Mass flow meters are typically factory-calibrated. However, field calibration may be needed in some situations. This ensures the meter is accurate for the actual process fluid.

For Coriolis meters, calibration is done by comparing the meter output with a known mass under controlled flow. This may involve using a weighing scale or a known volume with known density.

For thermal meters, calibration is based on gas type. Since different gases carry heat differently, the calibration must match the gas being used. Some models allow the user to select gas settings from the device menu.

After calibration, confirm that the meter shows correct readings under normal flow. If readings are off, check for air in the line, vibration, or sensor fouling.

Some meters come with a zeroing function. This should be performed when there is no flow in the pipe. It resets the sensor baseline to improve accuracy.

Operating the Meter

Once installed and calibrated, mass flow meters operate with minimal input. Most models have a display that shows flow rate, totalized flow, and sometimes temperature or density. These values can be monitored locally or through remote control systems.

Some meters have analog outputs like 4-20 mA, while others use digital protocols such as Modbus or HART. These outputs allow integration with SCADA systems or PLCs.

Users should monitor the readings for sudden changes. If flow drops or spikes unexpectedly, there may be a process problem. It could also be a sign that the meter needs cleaning or recalibration.

In batch operations, the meter can be used to deliver precise amounts of fluid. When the target mass is reached, a signal can be sent to stop the pump or open a valve. This ensures accurate delivery every time.

For safety, some meters have alarm settings. These can trigger warnings if the flow goes above or below safe limits.

Maintaining the Meter

Mass flow meters require little maintenance, but regular checks are still important. The frequency depends on the application, fluid type, and environment.

Inspect the display for any error codes. These codes are often explained in the user manual. Common errors include sensor faults, zero drift, or power issues.

Periodically check the physical condition of the meter. Look for signs of corrosion, wear, or loose connections. In dusty or wet environments, clean the display and housing with a soft cloth.

For Coriolis meters, inspect for vibration or air bubbles in the line. These can cause unstable readings. If buildup forms inside the sensor tubes, clean them according to the manufacturer’s guidelines.

Thermal mass meters may require cleaning of the sensing elements. This should be done carefully to avoid damaging the sensors. Use only approved cleaning fluids and tools.

Calibration should be verified once or twice per year, or more often for critical processes. Keep a log of calibration dates and results. This helps maintain traceability and quality control.

If the meter is not in use for long periods, it should be removed, cleaned, and stored in a dry place. Protect it from shocks or moisture during storage.

Troubleshooting Common Issues

If the meter is not reading correctly, first check for flow disturbances. These include pulsating flow, bubbles, or incorrect installation.

Make sure the power supply is stable. For digital meters, ensure that communication settings match the host system.

If the reading is too low or zero, check for blocked lines or closed valves. For thermal meters, verify that the gas matches the programmed gas type.

If readings fluctuate, inspect for vibration or air in the system. These can interfere with the sensors.

Always refer to the troubleshooting guide provided by the manufacturer. If problems persist, contact technical support for advice.

Conclusion

Mass flow meters are powerful tools for accurate fluid measurement. Their success depends on correct use, from installation to daily operation and maintenance. By following these instructions, users can ensure long-term reliability and performance.

Mass flow meters reduce waste, improve product quality, and enhance process control. They work in many industries and for many types of fluids. Understanding how to use them properly will help operators get the most value from their investment.